A) Features and Benefits:
• Shear Skirt Field Membrane Terminations with Deck
to Base Air Seal Membrane
B) Detail Drawings Gallery:A Gallery of all Detail Drawings
C) Detail Drawings by Name:
Shear Skirt Angle Change Termination…to Air Seal the Wall to The
Existing Roof Membrane On Non Fastenable Air Permeable Roof Decks
For Curbs and Perimeters Under 30in. High 2ft Two Foot Shear Skirt.
• 2FT-CEPDM-SS-CU Layout1: Using Reinforced C-EPDM
• 2FT-CEPDM-SS-CU-NR Layout1: Using Non-Reinforced C-
EPDM
• 2FT-TPO-SS-CU Layout1: With TPO or PVC Used
Shear Skirt Angle Change Termination … To Air Seal the Wall to the
Existing Roof Membrane On Non-Fastenable Air Permeable Roof Decks
For Curbs and Perimeters Under 30′ High 3′ 4″ Shear Skirt.
• 3FT-CEPDM-SS-CU Layout1: Using Reinforced C-EPDM
• 3FT-CEPDM-SS-CU-NR Layout1: Using Non-Reinforced C-
EPDM
• 3FT-TPO-SS-CU Layout1:Using TPO or PVC
Shear Skirt Perimeter Gravel Stop Termination on Non-Fastenable Air
Permeable Roof Decks Used To Air Seal the Wall to the Existing Roof
Membrane.
• GS-CEPDM-SS Layout1:Using Reinforced C-EPDM
• GS-CEPDM-SS-NR Layout1:Using Non-Reinforced C-EPDM
• GS-TPO-SS Layout1:Using TPO or PCV
Preflashed Shear Skirt Angle Change Termination …To Air Seal the Wall
to the Existing Roof Membrane On Non-Fastenable Air Permeable Roof
Decks For Curbs and Perimeters Over 30ft. High 3ft. 4in. Shear Skirt.
• PREF-CEPDM-SS-CU Layout1:Using Reinforced C-EPDM
• PREF-CEPDM-SS-CU-NR Layout1:With Non Reinforced
C-EPDM Used
• PREF-TPO-SS-CU Layout1: With TPO or PVC Used
Reverse Ballasted Shear Skirt Angle Change Termination…To Air Seal the
Wall to the Existing Roof Membrane On Non-Fastenable Air Permeable
Roof Decks For Curbs and Perimeters Over 30ft. High 2ft. Two Foot Shear
Skirt.
• RB-2FT-CEPDM-SS-CU Layout1:Using Reinforced C- EPDM
• RB-2FT-CEPDM-SS-CU-NR Layout1:Using Non-Reinforced
C-EPDM
• RB-2FT-TPO-SS-CU Layout1:Using TPO or PVC
Reverse Ballasted Shear Skirt Angle Change Termination…To Air Seal
the Wall to The Existing Roof Membrane On Non-Fastenable Air
Permeable Roof Decks For Curbs and Perimeters Over 30ft. High 3ft. 4in.
Shear Skirt.
• RB-3FT-CEPDM-SS-CU Layout1:Using Reinforced C-EPDM
• RB-3FT-CEPDM-SS-CU-NR Layout1:Using Non-Reinforced
C-EPDM
• RB-3FT-TPO-SS-CU Layout1:Using TPO or PVC
Reverse Ballasted Shear Skirt Perimeter Gravel Stop Termination on Non-
Fastenable Air Permeable Roof Decks To Air Seal The Wall to the Existing
Roof Membrane.
• RB-GS-CEPDM-SS Layout1:Using Reinforced C-EPDM
• RB-GS-CEPDM-SS-NR Layout1:With Non-Reinforced C-
EPDM Used
• RB-GS-TPO-SS Layout1:With TPO or PVC Used
Reverse Ballasted Preflashed Shear Skirt Angle Change Termination To
Air Seal the Wall To The Existing Roof Membrane On Non-Fastenable Air
Permeable Roof Decks For Curbs and Perimeters Over 30ft. High 3ft. 4in.
Shear Skirt.
• RB-PREF-CEPDM-SS-CU Layout1:With Reinforced C-
EPDM
• RB-PREF-CEPDM-SS-CU-NR Layout1:With Non-
Reinforced C-EPDM
• RB-PREF-TPO-SS-CU Layout1: With TPO or PVC Used
Reverse Ballasted Shear Skirt Perimeter Gravel Stop Termination On Non
Fastenable Air Permeable Roof Decks Used To Air Seal The Wall To The
Existing Roof Membrane
• RB-RGS-CEPDM-SS Layout1:With Reinforced C-EPDM
• RB-RGS-CEPDM-SS-NR Layout1:With Non-Reinforced C-
EPDM
• RB-RGS-TPO-SS Layout1:With TPO Used
Shear Skirt Perimeter Gravel Stop Termination On Non-Fastenable Air
Permeable Roof Decks To Air Seal The Wall To The Existing Roof
Membrane.
• RGS-CEPDM-SS Layout1: Using Reinforced C-EPDM
• RGS-CEPDM-SS-NR Layout1: Using Non-Reinforced C-
EPDM (Info Upon Request)
• RGS-TPO-SS Layout1: Using TPO (Info Upon Request)
• SS- 01 Layout1:Raised Gravel Stop Adhered Shear Skirt to
Existing Smooth Surface Shear Skirt on a Raised Gravel Stop (80 MPH)
• SS- 02 Layout1:Raised Gravel Stop Adhered Shear Skirt
Under Compression to Existing Smooth Surface Shear Skirt on a
Raised Gravel Stop (80 MPH)
• SS- 03 Layout1:Raised Gravel Stop Adhered Shear Skirt
• SS- 04 Model:Reinforced Shear Skirt on Non-Fastenable Deck
• SS- 05 Model:Pre-Flashing of Perimeter and Penetrations with Air
Seal
• SS- 06 Model:Non Fastenable Decks Shear Skirt Rnf Mem. 3ft.
4in. Perimeter 2ft. Penetrations
• SS- 07 Layout1:C-EPDM Shear Skirt Fastened into VerticalWall
(80 MPH)
• SS- 08 Layout1:TPO Shear Skirt Fastened into Vertical Wall (80
MPH)
• SS- 09 Layout1:For Non Fastenable Wall Air Seal with Floating
Cricket (100 MPH)
• SS- 10 Layout1:2001 Company Perimeter Edge Detail At
Cricket Locations
• SS- 11 Layout1:Non Fastenable Wall Air Seal Reinforced Shear
Skirt Fastened to Deck
• SS- 12 Layout1:C-EPDM 55 MPH Wind Rider
• SS- 13 Layout1:.060 Mil Reinforced C-EPDM Shear Skirt (80
MPH)
• SS- 14 Layout1:.060 Mil Reinforced C-EPDM Shear Skirt – Wind
Rider 1 (100 MPH)
• SS- 15 Layout1:.060 Mil Reinforced C-EPDM Shear Skirt – Wind
Rider 2 (100 MPH)
• SS- 16 Layout1:Hurricane Vert Wall Shear Skirt or Direct
Reinforced Vertical Wall Membrane Termination (80 MPH)
• SS- 17 Layout1:Backwrap Shear Skirt Detail for Expansion Joint
at Angle Change (70 MPH)
D) Written Specifications:
Summary Specification 2001 Co. Re-roof Over Two Existing
Roofs on a Monolithic Concrete Deck With Shear Skirts Up
to 100MPH Wind Rider*
Installation Pictures: