2001 Company – The Original Wind-Vented System


Check out our new podcast!

Hurricane Irma Results

Call us at: 203-575-9220

Fax us at: 203-573-0781

Email us at: TKelly@2001Company.com

The Wind-Vented System


What makes the 2001 Company Wind-Vented System unique? Our Equalizer Valves turn your flat roof into a breathing roof! The more the wind blows, the more your roof’s single-ply membrane (EPDM, TPO or PVC) is “vacuum-packed” against the building itself. When the wind dies down, the valves then breathe out any moisture that has been trapped under the roof’s membrane. No other roofing system can do this. This is an ongoing process; 24 hours a day, 365 days a year. Have piece of mind knowing that your roof is a working part of your building!

Below are graphics explaining how wind affects a building and how our valves work.

Features and Benefits of the 2001 Wind-Vented System

Lower Cost and Environmentally Friendlier than Conventional Re-roofing: No need to rip up your old roof and cart it off to the landfill.  We qualify as a third roof.  Hence we can roof over the existing roof, in some cases eliminating the additional cost for new insulation.  Gain the benefit of asbestos encapsulation as well. Take advantage of the significant savings by using our Wind-Vented System.

2001 Company’s Unique System Uses Significantly Less Material than Regular Systems: There is no need to mechanically adhere the roof membrane – save money on small items like screws and glue.  We also offer our Kelly Green Board that is a better option to OSB, Plywood, or Gypsum.

Minimal Disruption to Ongoing Business During Installation: Our Wind-Vented System doesn’t require you to rip off your old roof, keeping the interior of your building dry and safe from debris.

2001 Company has Superior Quality and Tested Performance: The superior air sealing quality of our roofs makes them extremely energy efficient and have had extensive National Laboratory Testing. Underwriters Laboratory (UL) – USA and National Research Council Canada – Canada

Continuous Self-Drying of Wet Roofs with Wind-Vented / Negative Pressure System: Upward migration of water vapor is vacuumed out of the roof assembly through one way valves placed in wind vortex intensity areas of a building perimeter.

2001 Company Thermal Performance: Our Wind-Vented System creates increased thermal performance and mitigation of mold, mildew and fungi.

45 Year Track Record of Weathering Sun, Wind, Rain, and Snow: We are the original Wind-Vented System.  2001 Co. uses only quality membranes and adhesives. Our air seal techniques were developed in house. We have installed roofs in every one of the 50 states, as well as the Virgin Islands and Puerto Rico.

Simplicity in Future Maintenance with up to 50 Year Warranties

High Wind Resistance – up to 200 MPH

Solar Ready

Building Code Approved

Installed by Local Trained Professionals

Kelly Green board

Our commitment to customer service is our most important asset. We look forward to serving you!